Home ProductsHeating And Cooling Heat Pump

17.6Kw Stainless Steel Casing Heating and Cooling Heat Pump Danfoss Expansion Valve

17.6Kw Stainless Steel Casing Heating and Cooling Heat Pump Danfoss Expansion Valve

17.6Kw Stainless Steel Casing Heating and Cooling Heat Pump Danfoss Expansion Valve

Product Details:

Place of Origin: China
Brand Name: POWERWORLD
Certification: CE, ERP, CB, EN14511
Model Number: MG-060-KFXLN

Payment & Shipping Terms:

Minimum Order Quantity: 1 units
Price: USD 998 to 1729 per units
Packaging Details: Carton box with wooden pallets
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 5000 units per month
Detailed Product Description
Cabinet: Stainless Steel Cabinet / Powder Coated Steel Evaporator: L-2/990*1200/φ9.52
Net Weight/Gross Weight: 155KG/165KG AC Contactor: (220V-25A)
Motor (with Capacitance): 90W*2(5μf) Body Size(W*D*H): 1110*490*1260mm

17.6Kw Stainless Steel Casing Heating and Cooling Heat Pump Danfoss Expansion Valve

 
Heating And Cooling Heat Pumps Parameters:
Product model PF030-KFXLN-S PF030-KFXLN PF045-KFXLN-S PF050-KFXLN PF060-KFXLN
Parameters Cooling Cooling capacity(kW) 6.4 7.6 11 12.6 14.5
Cooling input power(kW) 2.1 2.6 3.7 4.2 4.9
Rated current (A)  10.3 4.6 5.6 7.3 8.1
EER 3.05 2.92 2.97 3.00 2.96
Heating* Heating capacity(kW) 8.1 9.1 13.6 15.1 17.6
Heating input power(kW) 2.4 2.7 4.1 4.4 5.2
Rated current (A)  10.9 4.8 18.6 7.5 8.5
COP   3.38 3.37 3.32 3.43 3.38
 Working  area  -7~43℃
IP Grade (Level of protection) IPX4 IPX4 IPX4 IPX4 IPX4
Anti-electric shock Rate
Noise (dB(A)) ≤55 ≤55 ≤55 ≤58 ≤58
Net weight/Gross weight(kg) 100/106 100/106 120/126 145/155 155/165
Diameter of pipe (mm) DN25 DN25 DN25 DN25 DN25
Standard Configuration Metel plate Galvanized steel/Spray/Gray Galvanized steel/Spray/Gray Galvanized steel/Spray/Gray Galvanized steel/Spray/Gray Galvanized steel/Spray/Gray
Body size(W*D*H) 830*490*1160 830*490*1160 1110*490*1260 1110*490*1260 1110*490*1260
Compressor Copeland  
Refrigerant R407C 
Power supply 220V/50Hz 380V/50Hz 220V/50Hz 380V/50Hz 380V/50Hz
Condenser Tube in tube heat exchanger 
Evaporator U-2/1200*550/φ9.52  U-2/1200*550/φ9.52  L-2/990*1200/φ9.52  L-2/990*1200/φ9.52  L-2/990*1200/φ9.52 
Four-way valve DSF-11 DSF-11 DSF-11 DSF-20 DSF-20
Expansion valve Danfoss /Emerson
AC contactor (220V-25A) (220V-12A) (220V-25A) (220V-18A) (220V-25A)
Motor (with capacitance) 90W*1(5μf) 90W*1(5μf) 90W*2(5μf) 90W*2(5μf) 90W*2(5μf)
Fan φ490*1 φ490*1 φ490*2 φ490*2 φ490*2
Controller

Single System

(Motorola Chip)

Single System

(Motorola Chip)

Single System

(Motorola Chip)

Single System

(Motorola Chip)

Single System

(Motorola Chip)

Low-voltage switch 0.15/0.32MPa 0.15/0.32MPa 0.15/0.32MPa 0.15/0.32MPa 0.15/0.32MPa
High-voltage switch 3.0/3.6MPa  3.0/3.6MPa  3.0/3.6MPa  3.0/3.6MPa  3.0/3.6MPa 
Power line connect with unit 3*2.5mm2 3*2.5mm2+2*1.5mm2 3*4mm2 3*4mm2+2*2.5mm2 3*6mm2+2*2.5mm2
Package Polywood packing
Remark:Cooling working condition:Inlet water temperature 12℃, Outlet water temperature 7℃, Dry bulb temperature 35℃, Wet bulb temperature 24℃.
       Heating working condition: Inlet water temperature 40℃, Outlet water temperature 45℃, Dry bulb temperature 7℃, Wet bulb temperature6℃.

17.6Kw Stainless Steel Casing Heating and Cooling Heat Pump Danfoss Expansion Valve

 

Heating and Cooling Heat Pumps Description
 
1. Environmental friendly and safe
Electric parts and water system is completely cut off, ensuring security water use, no pollution to the atm

-osphere and free of greenhouse effect and it is the safest water heater
 
2. Wide climatic zone adaptability
Our heat pumps with special designing possess better climatic adaptability, can work from -25℃ to 43℃.
 
3. Energy-saving
Heat pump water heater is a high efficient transferring heating equipment which is driven by electricity.

The operating cost is only 1/4 of electric water heater, 1/3 of gas water heater.
 
4. Automatic intelligent control system
Adopting intelligent computerized automatic control system, no manual cost, easy to operate, convenient,

make heat pump work safely and reliably.
Control panel with modularized unit design can control more flexible heat pumps packs, with user-friendly

operating system interface, easy to operate..
 
5. Advanced testing methods
Adopting world-class Enthalpy potential laboratory to test heat pumps, except basic testing items, we also

test heat pump in the ambient of temperature of  -30℃ to test our heat pump performance.
 
6. Widely used
Heat pump is applied to hot water for household and commercial use like families, schools, hospitals, show

-er center, swimming pools, etc. and industrial use like electroplating, drying, etc.
17.6Kw Stainless Steel Casing Heating and Cooling Heat Pump Danfoss Expansion Valve

17.6Kw Stainless Steel Casing Heating and Cooling Heat Pump Danfoss Expansion Valve 
  
Competitive Advantage:


1. Strong SGCC Casing Dark Cyan Charming Design;
2. Smart control double systems;
3. Danfoss/Copeland/Emerson/Eaton etc. precise accessories are constructing outstanding quality
& high efficient performance.
4. Excellent for both hot water, heating & cooling, meeting all demands you need.

Welcome you visiting Power World heat pump website, please send us an inquiry and let us know your interests and requirements, we will reply you at once.
Wish you have a good day.

Contact Details
Shenzhen Power World New Energy Technology Co., Ltd.

Contact Person: Ms. Ida Ray

Tel: 86-0755-33850802

Fax: 86-0755-33850799

Send your inquiry directly to us (0 / 3000)