Power World Machinery Equipment Co.,Ltd. 

 

Enterprise Value: Sincerity, Practicality, Innovation.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsLow Temperature Heat Pump

EVI System Low Temperature Heat Pump With Automatic Defrosting

Certification
Good quality Ground Source Heat Pump for sales
Good quality Ground Source Heat Pump for sales
The EVI heat pump are running well for this winter. Thank you for your kind supports of training our install people!

—— Richard J. Roos

Best heat pump that I have bought from China, perfect performance and good after sales support!

—— Carl Eriksson

I'm Online Chat Now

EVI System Low Temperature Heat Pump With Automatic Defrosting

China EVI System Low Temperature Heat Pump With Automatic Defrosting supplier

Large Image :  EVI System Low Temperature Heat Pump With Automatic Defrosting

Product Details:

Place of Origin: China
Brand Name: Power World
Certification: CE, CB, IEC, EN14167, SAA, C-Tick, Rohs
Model Number: MG-100KFLW

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: USD $1589 ~ $ 2799 / set
Packaging Details: Polywood packing
Delivery Time: 7-30 days after receiving payment
Payment Terms: T/T, L/C, Western Union, MoneyGram
Supply Ability: 6000 units per month
Contact Now
Detailed Product Description
Refrigerant: R407C Compressor: Copeland EVI Compressor
Power Supply: 380V/50Hz/3Ph Throttle Unit: Thermostatic Expansion Valve
Economy Unit(EVI Heating Exchanger): Plate Type FHC022-17*2 COP: 3.5
Power Supply Line Size: 3*4mm2+2*2.5mm2 Motor (with Capacitance): YSWF102L50P6-625N-550*2

 

EVI System Low Temperature Heat Pump With Automatic Defrosting

 

 

Low Temperature Heat Pump Futures:

 

Feature 

 

1)       EVI compressor special designed for high COP (Coefficient of Performance): 4.5 even in bad weather condiction or area.

2)       Base frame and externel panels made of galvanized powder coated steel

3)       Water exchanger equipped with high efficiency tube in shell heat exchanger

4)       Reliable compressor with R407C refrigerant

5)       Stable water flow switch & backflow proof.

6)       Fully sealed control box with water proof level IPX4

7)       Intelligent microprocessor double control systems with Motorola IC, auto memory & nighlight.

8)       Air exchanger (fin-coil) with hydrophilic coating

9)       Lowest noise that 6T fan motor & Mitsubishu/Copeland high efficient compressor, thermostability PE material with bond for soundproof & heat preservation.

 

 

DC Inverter Heat Pump,EVI Split Type ,Heat Pump Heat evi Inverter

 

 

 

DC Inverter Heat Pump,EVI Split Type ,Heat Pump Heat evi Inverter

EVI System Low Temperature Heat Pump With Automatic Defrosting

 

EVI System Low Temperature Heat Pump With Automatic Defrosting

 

Low Temperature EVI Heat Pumps Parameters:

 

Product model MG-030KFLW   MG-030KFLW   MG-050KFLW   MG-100KFLW   MG-200KFLW  
Standard Configuration Metel plate

Galvanized steel/

Spray/Gray

Galvanized steel/

Spray/Gray

Galvanized steel/

Spray/Gray

Galvanized steel

/Spray/Gray

Galvanized stee

l/Spray/Gray

Body size(W*D*H) 830*490*1160 830*490*1160 1110*490*1260 1580*800*1600 2000*1100*2080
Compressor Copeland  Copeland  Copeland  Copeland  Copeland 
Refrigerant R407C/1.7kg R407C/1.7kg R407C/3.3kg R407C/3.3kg*2 R407C/7kg*2
Power supply 220V/50Hz 380V/50Hz 380V/50Hz 380V/50Hz 380V/50Hz
Economy unit(EVI heating exchanger) Plate type FHC022-17

Plate type

FHC022-17

Plate type FHC022-17

Plate type

FHC022-17*2

Plate type

FHC022-34*2

Four-way valve DSF-11 DSF-11 DSF-20 DSF-20*2 DSF-35*2
Thermostatic expansion valve

Emerson

(3+1 ton of

refrigeration)

Thermostatic

expansion valve

(3+1 ton

of refrigeration)

AC contactor (220V-25A) (220V-12A) (220V-18A) (220V-18A)*2 (220V-38A)*2
Motor (with capacitance) 90W*1(5μf) 90W*1(5μf) 90W*2(5μf)

YSWF102L50P6-

625N-550*2

YSWF127L50P6

-840N-710*2

Fan φ490*1 φ490*1 φ490*2
Controller

Dual system

(Motorola Chip)

Dual system

(Motorola Chip)

Dual system

(Motorola Chip)

Dual system

(Motorola Chip)

Dual system

(Motorola Chip)

Low-voltage switch 0.05/0.15MPa  0.05/0.15MPa  0.05/0.15MPa  0.05/0.15MPa  0.05/0.15MPa 
High-voltage switch 2.6/3.2MPa  2.6/3.2MPa  3.0/3.6MPa  3.0/3.6MPa  3.0/3.6MPa 
Power line connect with unit 3*2.5mm2 3*2.5mm2+2*1.5mm2

3*4mm2+2*

2.5mm2

3*6mm2+2*2.5mm2 3*10mm2+2*4mm2
Package Polywood packing

Polywood

packing

Polywood

packing

Polywood

packing

Polywood packing
Parameters Ambient 200C Water 550C Heating capacity (kW)  10.3 11.3 20.4 40.8 75.2
Input power (kW)  3.05 3.34 5.83 11.66 20.1
Rated current (A)  12 5 9 18 35.2
COP (Coefficient of Performance) 3.38 3.38 3.50 3.50 3.74
Production capacity (L/H) 221 243 439 877 1616
Ambient 70C Water 550C Heating capacity (kW)  9.11 10 18 36 66.5
Input power (kW)  3.04 3.4 5.8 11.6 20
COP (Coefficient of Performance) 3.00 2.94 3.10 3.10 3.33
Production capacity (L/H) 196 215 387 774 1429
Ambient 70C Water 450C Heating capacity (kW)  9.1 10.1 18.3 36.6 65.8
Input power (kW)  2.45 2.67 4.7 9.4 16.5
COP (Coefficient of Performance) 3.71 3.78 3.89 3.89 3.99
Production capacity (L/H) 196 217 393 787 1414
Ambient 70C Water 350C Heating capacity (kW)  9.17 10.2 18.6 37.2 65.8
Input power (kW)  1.99 2.12 3.84 7.68 14.5
COP (Coefficient of Performance) 4.61 4.81 4.84 4.84 4.54
Production capacity (L/H) 197 219 400 800 1414
Ambient 20C Water 450C Heating capacity (kW)  8.08 8.9 16 32 57.7
Input power (kW)  2.35 2.55 4.58 9.16 16.4
COP (Coefficient of Performance) 3.44 3.49 3.49 3.49 3.52
Production capacity (L/H) 174 191 344 688 1240
Ambient 20C Water 350C Heating capacity (kW)  8.06 8.9 16.1 32.2 57.5
Input power (kW)  1.89 2.01 3.71 7.42 14.5
COP (Coefficient of Performance) 4.26 4.43 4.34 4.34 3.97
Production capacity (L/H) 173 191 346 692 1236
Ambient -70C Water 450C Heating capacity (kW)  6.31 6.8 12.4 24.8 44.2
Input power (kW)  2.45 2.6 4.34 8.68 16
COP (Coefficient of Performance) 2.58 2.62 2.86 2.86 2.76
Production capacity (L/H) 136 146 267 533 950
Ambient -70C Water 350C Heating capacity (kW)  6.18 6.6 12.3 24.6 43.7
Input power (kW)  2 1.98 3.56 7.12 13.9
COP (Coefficient of Performance) 3.09 3.33 3.46 3.46 3.14
Production capacity (L/H) 133 142 264 529 939
Ambient -150C Water 450C Heating capacity (kW)  5.1 5.4 9.81 19.62 34.5
Input power (kW)  2.43 2.55 4.17 8.34 15.5
COP (Coefficient of Performance) 2.10 2.12 2.35 2.35 2.23
Production capacity (L/H) 110 116 211 422 742
Ambient -150C Water 350C Heating capacity (kW)  4.9 5.1 9.5 19 32.7
Input power (kW)  2 2.03 3.39 6.78 12.7
COP (Coefficient of Performance) 2.45 2.51 2.80 2.80 2.57
Production capacity (L/H) 105 110 204 408 703
Ambient -200C Water 350C Heating capacity (kW)  4.2 4.3 8 16 26.5
Input power (kW)  1.9 1.8 3.13 6.26 11.7

COP

(Coefficient of Performance)

2.21 2.39 2.56 2.56 2.26
Production capacity (L/H) 90 92 172 344 570

Rated outlet

hot water

temperature (℃)

55 55 55 55 55

Highest outlet

hot water

temperature(℃)

60 60 60 60 60

IP Grade

(Level of protection)

IPX4 IPX4 IPX4 IPX4 IPX4
Anti-electric shock Rate
Noise (dB(A)) ≤55 ≤55 ≤58 ≤66 ≤66

Net weight/

Gross weight((kg)

100/106 100/106 145/155 298/313 585/645
Diameter of pipe (mm) DN25 DN25 DN25 DN32 DN65

 