Power World Machinery Equipment Co.,Ltd. 

 

Enterprise Value: Sincerity, Practicality, Innovation.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsSplit System Heat Pump

Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System

Certification
Good quality Ground Source Heat Pump for sales
Good quality Ground Source Heat Pump for sales
The EVI heat pump are running well for this winter. Thank you for your kind supports of training our install people!

—— Richard J. Roos

Best heat pump that I have bought from China, perfect performance and good after sales support!

—— Carl Eriksson

I'm Online Chat Now

Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System

China Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System supplier
Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System supplier Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System supplier Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System supplier Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System supplier Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System supplier

Large Image :  Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System

Product Details:

Place of Origin: China
Brand Name: Power World
Certification: CE, IEC, EN14511
Model Number: #MG-050-KFLWS

Payment & Shipping Terms:

Minimum Order Quantity: 1 pcs
Price: negotiation
Packaging Details: Plywood package
Delivery Time: 15-20 working days after received your payment
Payment Terms: T/T or western Union, D/A, L/C, D/P, MoneyGram
Supply Ability: 5,500pcs per month
Contact Now
Detailed Product Description
Application: Floor & Daily Water Heating Feature 1: Auto-swich Domestic Water To Floor Heating
Feature 2: Weekly Uperization Work Condition: -25℃ To 43℃
Water Outlet: 35℃ To 60℃ COP: 3.92
Heating Outlet: 18.8kw Power Input: 4.80kw
Compressor: COPELAND EVI Refrigerant: R407C/oem
Power Supply: 380-440V/50Hz Noise In 1M: Below 58 DB(A)

Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System to Interior Heating Domestic Water

 

Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System Features:

 
1. Super low temperature working condition and outstanding defrosting design

Big Indoor Unit with key configuration in the house and only fan+motor and evaperator outside in environment, EVI technology to strength its performance in cold area, especially during -2DegC to 3DegC and exceeding -25DegC ambient temperature, so as to supply hot water constantly for daily usage, house heating or 55DegC domestic water.

 

2. Environmental friendly and safe
Electric parts and water system is completely cut off, ensuring security water use, no pollution to the atmosphere and free of greenhouse effect and it is the safest water heater
 
3. Wide climatic zone adaptability
Our heat pumps with splinched design possess better climatic adaptability, can work from -25degrees to 43degrees.
 
4. Energy-saving
Heat pump water heater is a high efficient transferring heating equipment which is driven by electricity. The operating cost is only 1/4 of electric water heater, 1/3 of gas water heater.
 
5. Automatic intelligent control system
Adopting intelligent computerized automatic control system, no manual cost, easy to operate, convenient, make heat pump work safely and reliably.
Control panel with modularized unit design can control more flexible heat pumps packs, with user-friendly 
operating system interface, easy to operate..
 
6. Advanced testing methods
Adopting world class Enthalpy potential laboratory to test heat pumps, except basic testing items, we also test heat pump in the ambient of temperature of  -30℃ to test our heat pump performance.
 
7. Widely used
Heat pump is applied to hot water for household and commercial use like families, schools, hospitals, shower center, swimming pools, etc. and industrial use like electroplating, drying, etc.

 
Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System Specification:

 

EVI Split Low Temperature Air Source Heat Pump
Item No. #MG-030A-KFLWS #MG-030B-KFLWS #MG-050-KFLWS
Parameters Heating* Outlet (kW) 10.5 11.5 18.8
Input power (kW) 2.7 2.9 4.8
Rated current (A) 12.4 5.9 9
COP 3.89 3.97 3.92
HotWater Outlet(L/H) 226 247 404
Heating** Outlet (kW) 8.4 9.1 15.0
Input power (kW) 2.6 2.8 4.7
Rated current (A) 12.3 5.8 8.9
COP 3.23 3.25 3.19
HotWater Outlet(L/H) 157 170 280
Heating*** Outlet(kW) 8.2 9.1 14.8
Input power(kW) 2.25 2.43 4
Rated current (A) 10.3 4.9 7.5
COP 3.64 3.74 3.70
Rated outlet water temp.(℃) 55 55 55
Max outlet hot water(℃) 60 60 60
Work Condition -25~43℃
IP Grade IPX4
Standard Configuration Anti-electric shock Rate I
Noise in 1M (dB(A)) ≤55 ≤55 ≤58
N.W./G.W.(kg) 140/155 140/155 190/210
Diameter of pipe (mm) DN25 DN25 DN25
Housing Material Galvanized steel/Spray/Gray
Size(W*D*H) Outdoor unit 830*310*710 930*390*1270
Intdoor unit 660*385*900
Compressor Copeland
Refrigerant R407C
Power supply 220V/50Hz 380V/50Hz 380V/50Hz
Condenser Efficient tank heat exchanger
EVI heating exchanger Plate type MTB020-17 Plate type MTB020-17
Evaporator U-2/1200*550/φ9.52 L-2/990*1200/φ9.52
Four-way valve DSF-11 DSF-20
Expansion valve Danfoss /Emerson
AC contactor (220V-25A) (220V-18A)
Motor (with capacitance) 50W*2(4μf*2) 90W*2(5μf)
Fan φ420*2 φ490*2
Controller Single System(Motorola Chip)
Low-voltage switch 0.05/0.15MPa 0.05/0.15MPa
High-voltage switch 3.0/3.6MPa 3.0/3.6MPa
Cable size 3*2.5mm2 3*4mm2+2*2.5mm2
Package Polywood packing
Heating* work condition: Inlet water temp.15℃,outlet water temp.55℃,dry bulb temp.20℃, wet bulb temp.15℃.
Heating** work condition: Inlet water temp.9℃, outlet water temp.55℃,dry bulb temp.7℃, wet bulb temp.6℃.
Heating*** work condition: Inlet water temp. 30℃, outlet water temp. 35℃, dry bulb temp. 7℃, wet bulb temp.6℃.
Quality warranty: 5-year for compressor, 18-month for whole unit.
Sampletime: 15-20 days. Leadtime: 30-35 days after order approval.

 

Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System Applications:

 

Business Organizations

supermarket, large-scale shopping malls, exclusive agency, chain shops, large-scale 
sales, star-rated hotels, restaurants, travel agencies, pharmacy.

Financial Organizations

Banks, negotiable securities, funds, insurance companies, pawnshops;
Non-profit Organizations: Telecommunications, post offices, hospital, schools;

Public Places

subway, airports, stations, gas stations, toll stations, bookstores, parks,  exhibition halls, 
stadiums, museums, convention centers, ticket agencies, HR market, lottery  centers; 
Real Estate Property: Apartments, villas, offices, commercial buildings, model  rooms, 
property brokers;

Entertainments

Movie theaters, fitness halls, country clubs, clubs, massage rooms, bars, cafes, 
Internet bars, beauty shops, golf course

 
Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System COP Diagram:

1)For domestic hot water heating

Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System

2) For space heating

Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System

 

Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System Installation Principle:

                 Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System

 

Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System Installation between Indoor & Outdoor Unit:

 

Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump SystemSplinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump SystemSplinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump SystemSplinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump SystemSplinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump SystemSplinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System
Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System Company Certificates:  
Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System

Splinched Big Indoor Unit Freezing Region Exhausted Air Water Heater Pump System welcome to visit our Power World factory in Shenzhen!

Contact Details
Shenzhen Power World New Energy Technology Co., Ltd.

Contact Person: Ms. Ida Ray

Fax: 86-0755-33850799

Send your inquiry directly to us (0 / 3000)