Power World Machinery Equipment Co.,Ltd. 

 

Enterprise Value: Sincerity, Practicality, Innovation.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsHigh COP Heat Pump

-20DegC Monobloc DC Inverter Air to Water Heater Pump for Chilling Heating

Certification
Good quality Ground Source Heat Pump for sales
Good quality Ground Source Heat Pump for sales
The EVI heat pump are running well for this winter. Thank you for your kind supports of training our install people!

—— Richard J. Roos

Best heat pump that I have bought from China, perfect performance and good after sales support!

—— Carl Eriksson

I'm Online Chat Now

-20DegC Monobloc DC Inverter Air to Water Heater Pump for Chilling Heating

China -20DegC Monobloc DC Inverter Air to Water Heater Pump for Chilling Heating supplier
-20DegC Monobloc DC Inverter Air to Water Heater Pump for Chilling Heating supplier -20DegC Monobloc DC Inverter Air to Water Heater Pump for Chilling Heating supplier -20DegC Monobloc DC Inverter Air to Water Heater Pump for Chilling Heating supplier

Large Image :  -20DegC Monobloc DC Inverter Air to Water Heater Pump for Chilling Heating

Product Details:

Place of Origin: China
Brand Name: Power World
Certification: CE, ROHS, EN14511
Model Number: #PF030-KFXLND-S

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: Packed in carton firstly,and then reinforced with wooden case for outer packing
Delivery Time: 20 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 8,000 sets per month
Contact Now
Detailed Product Description
Function: Chilling/Heating/Hot Water COP Scope: 3.69 To 4.75
EER Scope: 2.41 To 3.27 Heating Outlet: 6.65kw To 13.3kw
Chilling Outlet: 4.90kw To 8.90kw Compressor: DC Inverter
Refrigerant Oil: R410A Heating Input: 1.4kw To 3.6kw
Work Condtion: -20℃ To 43℃ Water Outlet: 07℃ To 60℃

-20DegC Monobloc DC Inverter Air to Water Heater Pump for Chilling Heating and Domestic Hot Water

 

-20DegC Monobloc DC Inverter Air to Water Heater Pump Description:

 

1) DC Inverter compressor special designed for high COP (Coefficient of Performance): 4.75 even in bad weather condiction or area.                   

2) Base frame and externel panels made of galvanized powder coated steel                      

3) Water exchanger equipped with high efficiency tube in shell heat exchanger                      

4) Reliable compressor with R410A refrigerant                  

5) Stable water flow switch & backflow proof.                     

6) Fully sealed control box with water proof level IPX4                   

7) Intelligent microprocessor double control systems with Motorola IC, auto memory & nighlight.

8) Air exchanger (fin-coil) with hydrophilic coating                   

9) Thermostatic heating element for evaporator, anti-frosting every 30 minutes per day.

10) EVERY capillary tube of DANFOSS/EMERSON expansion valve full-covered by silicon/soft pipe refucing buffer friction, subtle vibraction from compressor/fan, keeping strong as 10-year working life,even longer.                       

11) No need of auxiliary electrical heating and works well even at -20 ℃.

12) Lowest noise that 6T dc inverter fan motor & Mitsubishu high efficient compressor, thermostability PE material with bond for soundproof & heat preservation.

 

-20DegC Monobloc DC Inverter Air to Water Heater Pump Specification:

 

DC Inverter Heat Pump for cooling/heating & DHW
Item No. PF030-KFXLND-S PF050-KFXLND
Cooling Cooling capacity(kW) 7.7 12.8
Capacity Range Min/Max(kW) 4.9/8.9 8.2/14.8
Input power(kW) 2.6 4.2
Input power Min / Max (kW) 1.5/3.7 2.5/6.0
Rated current (A) 12.7 20.5
Current Range Min/Max (A) 7.3/18.1 12.2/29.3
EER 2.96 3.05
EER Range Min/Max 2.41/3.27 2.47/3.28
Heating Outlet(kW) 10.2 16.5
Outlet Range Min/Max (kW) 6.65/13.3 10.7/21.5
Input Power (kW) 2.4 3.9
Input Power Range Min/Max(kW) 1.4/3.6 2.2/5.9
Rated Current (A) 11.7 19
Current Range Min/Max (A) 6.8/17.6 10.7/28.7
COP 4.25 4.23
COP Range Min/Max 3.69/4.75 3.65/4.9
DHW Outlet(kW) 8.3 13.5
Outlet Range Min/Max (kW) 5.4/10.8 8.8/17.6
Input Power(kW) 2.5 4.1
Input Power Range Min/Max(kW) 1.4/3.8 2.3/6.2
Rated Current (A) 12 20
Current Min/Max (A) 6.8/18.5 11.2/30.2
COP 3.32 3.29
COP Range Min/Max 2.84/3.86 2.84/3.83
Refrigerant R410A
Power supply 220V/50Hz
Working area -20~43℃
Water circulation (m³/H) 1.75 2.84
Water pressure drop (kPa) 25 30
IP Grade (Level of protection) IPX4 IPX4
Anti-electric shock Rate I I
Noise in 1M dB(A) ≤53 ≤58
Net weight/Gross weight(kg) 125/135 155/165
Diameter of pipe (mm) DN25 DN25
Body size(W*D*H) 1115*425*710 1110*490*1260
Packing size(W*D*H) 1180*480*850 1180*540*1390
Loading QTY (20GP/40GP/40HQ) 48/100/150 18/42/42
Cooling work condition: Inlet water temp. 12℃, outlet water temp. 7℃, dry bulb temp. 35℃, wet bulb temp. 24℃.
Heating work condition: Inlet water temp. 30℃, outlet water temp. 35℃, dry bulb temp. 7℃, wet bulb temp. 6℃.
DHW work condition: Inlet water temp. 15℃, outlet water temperature 55℃, dry bulb temp. 7℃, wet bulb temp. 6℃.

 

 

-20DegC Monobloc DC Inverter Air to Water Heater Pump Applications:

 

Business Organizations

supermarket, large-scale shopping malls, exclusive agency, chain shops, large-scale sales, star-rated hotels, restaurants, travel agencies, pharmacy.

Financial Organizations

Banks, negotiable securities, funds, insurance companies, pawnshops;

Non-profit Organizations: Telecommunications, post offices, hospital, schools;

Public Places

subway, airports, stations, gas stations, toll stations, bookstores, parks, exhibition halls, stadiums, museums, convention centers, ticket agencies, HR market, lottery centers; Real Estate Property: Apartments, villas, offices, commercial buildings, model rooms, property brokers;

Entertainments

Movie theaters, fitness halls, country clubs, clubs, massage rooms, bars, cafes, Internet bars, beauty shops, golf course

 

 

-20DegC Monobloc DC Inverter Air to Water Heater Pump Competitive Advantages:

 

-20DegC Monobloc DC Inverter Air to Water Heater Pump for Chilling Heating

-20DegC Monobloc DC Inverter Air to Water Heater Pump for Chilling Heating

 

-20DegC Monobloc DC Inverter Air to Water Heater Pump Shipping:

 

-20DegC Monobloc DC Inverter Air to Water Heater Pump for Chilling Heating

-20DegC Monobloc DC Inverter Air to Water Heater Pump for Chilling Heating

-20DegC Monobloc DC Inverter Air to Water Heater Pump welcome to visit Power World heat pump factory in Shenzhen! Please send me email: hp@heatpumpcn.com or Phone/WhatsApp: +86-15099917097

Contact Details
Shenzhen Power World New Energy Technology Co., Ltd.

Contact Person: Ms. Ida Ray

Fax: 86-0755-33850799

Send your inquiry directly to us (0 / 3000)