Power World Machinery Equipment Co.,Ltd. 

 

Enterprise Value: Sincerity, Practicality, Innovation.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsHigh COP Heat Pump

Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHW

Certification
Good quality Ground Source Heat Pump for sales
Good quality Ground Source Heat Pump for sales
The EVI heat pump are running well for this winter. Thank you for your kind supports of training our install people!

—— Richard J. Roos

Best heat pump that I have bought from China, perfect performance and good after sales support!

—— Carl Eriksson

I'm Online Chat Now

Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHW

China Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHW supplier
Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHW supplier Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHW supplier Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHW supplier

Large Image :  Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHW

Product Details:

Place of Origin: China
Brand Name: PowerWorld
Certification: CE,IEC,ISO
Model Number: PF030/050-DC

Payment & Shipping Terms:

Minimum Order Quantity: 1unit
Price: 1000USD
Packaging Details: Plywood package .
Delivery Time: in 7 days for delivery .
Payment Terms: L/C, D/A, T/T, Western Union
Supply Ability: 100units / day
Contact Now
Detailed Product Description
Casing Color: Anti-rusting Spray Coating Package: Plywood Package
Heating Capacity: 9.5-17KW COP: Over 4.25
Compressor: Dual-rotary D/C Inverter Compressor Throttle Unit: Thermal Expansion Valve
Working Area: -20~43℃ Evaporator: Blue Hydrophilic Fin And Copper Tube Heat Exchanger

Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHW

 

 

What is the difference between a fixed and inverter system?

Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHW

Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHWFixed Speed System

Slowly gets to temperature as output rating is fixed. Then turns on and off to maintain room temperature.

Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHWInverter System

Increased output to achieve set temperature faster. Then varies the output to maintain a constant room temperature.

Fixed speed

A fixed speed system only has a single speed compressor motor that is either on or off. It works similar to a single speed fan heater running at its only speed that switches off when the desired temperature is reached and switches on again when the temperature drops to a set level. As there is only one speed that the fixed speed system can run at, it takes a lot longer to get to the desired temperature. As such this tends to lead to a lot more power usage in comparison to inverter driven systems.

Advantages

  • Consistent Room Temperature - No Ups and Downs, Ons and Offs: Conventional heat pumps experience uncomfortable and extreme temperature fluctuations while INVERTER-driven pumps are able to self-adjust, providing consistent room temperature, even when the outdoor temperature dips below zero.
  • Consume Only The Energy You Need: INVERTER zoning systems deliver only the amount of hot air needed to achieve the desired temperature – no more, no less.
  • Heats Up Quickly: It takes traditional systems a very long time to reach the desired temperature, while the high rotation speeds of INVERTER systems allow for quick and efficient cooling and heating.
  • Energy Use is Even and Steady: Every time the compressor turns on in a traditional unit, energy consumption surges. On startup, INVERTER systems use less current, avoiding spikes in energy usage.

 

Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHW

Great EER Most Efficient Heat Pump For Floor Heating / Cooling And DHW

Product model PF030DC PF050DC
Cooling Cooling capacity(kW) 7.7 12.8
Cooling capacity Min / Max(kW) 4.9/8.9 8.2/14.8
Cooling input power(kW) 2.6 4.2
Cooling input power Min / Max (kW) 1.5/3.7 2.5/6.0
Rated current (A) 12.7 20.5
Current Min / Max (A) 7.3/18.1 12.2/29.3
EER 2.96 3.05
EER Min / Max 2.41/3.27 2.47/3.28
Heating Heating capacity(kW) 10.2 16.5
Heating capacity Min / Max (kW) 6.65/13.3 10.7/21.5
Heating input power(kW) 2.4 3.9
Heating input power Min / Max (kW) 1.4/3.6 2.2/5.9
Rated current (A) 11.7 19
Current Min / Max (A) 6.8/17.6 10.7/28.7
COP 4.25 4.23
COP Min / Max 3.69/4.75 3.65/4.9
DHW Heating capacity(kW) 8.3 13.5
Heating capacity Min / Max (kW) 5.4/10.8 8.8/17.6
Heating input power(kW) 2.5 4.1
Heating input power Min / Max (kW) 1.4/3.8 2.3/6.2
Rated current (A) 12 20
Current Min / Max (A) 6.8/18.5 11.2/30.2
COP 3.32 3.29
COP Min / Max 2.84/3.86 2.84/3.83

 

* Copeland Compressor :

Dual-rotary D/C Inverter Compressor .

* Fan:

Well selected axial T6 fan motor combined with large fan blade, which provide heavy air blow at low rotate speed, reducing vibration and noise.

*Danfoss Electric Expansion Valve:

Danfoss 500 steps Electronic Expansion valve, with more precise control of refrigerant flow system, which optimize heat pump working capacity and efficiency under different ambient conditions.

* High Efficient Tube in Shell Condenser (heat exchanger)

Optimize design of both inner and outer screwed tube, it helps to increase heating exchange efficiency, and provide better heating capacity. The special design of liquid refrigerant circulating tube on the bottom of condenser ensures the heat pump system run smoothly in severe working condition.

*Original DuPont Refrigerant

Original DuPont refrigerant, better efficient and ECO friendly, ensure heat pump run reliably and smoothly.

* Heat exchanger

Blue hydrophilic fin and copper tube heat exchanger.

*Outfitting both liquid-storage & gas-liquid separator

Our heat pump outfitting both liquid-storage and gas-liquid separator ensures units run smoothly in different kinds of extreme hostile environment.

*Eaton (USA) AC contactor & Thermal relay

High quality contactor and thermal relay can freely turn on/off more than 100,000 times.

* Humanized PCB Design

Military level PCB components, intelligent controlling program reinforced a reliable operation of the heat pump unit. Special colored wiring design on the PCB provides great convenience in installation and further maintenance.

*Wide Voltage Transformer

220V-240V or 380V-440V AC, 50/60Hz wide voltage transformer in case of voltage fluctuation, ensures unit work smoothly. Current transformer protecting over-current ensure unit working current more accurate.

*Aerial Noise Isolated Material

By using high quality aerial noise isolated material, noise and vibration is avoided perfectly.

 

Contact Details
Shenzhen Power World New Energy Technology Co., Ltd.

Contact Person: Ms. Ida Ray

Fax: 86-0755-33850799

Send your inquiry directly to us (0 / 3000)