Power World Machinery Equipment Co.,Ltd. 

 

Enterprise Value: Sincerity, Practicality, Innovation.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsHigh COP Heat Pump

3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511

Certification
Good quality Ground Source Heat Pump for sales
Good quality Ground Source Heat Pump for sales
The EVI heat pump are running well for this winter. Thank you for your kind supports of training our install people!

—— Richard J. Roos

Best heat pump that I have bought from China, perfect performance and good after sales support!

—— Carl Eriksson

I'm Online Chat Now

3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511

China 3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511 supplier
3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511 supplier 3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511 supplier 3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511 supplier

Large Image :  3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511

Product Details:

Place of Origin: China
Brand Name: Power World/OEM
Certification: CE, ROHS, EN14511, EN14825, UL
Model Number: #PF050DC

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: Packed in carton firstly,and then reinforced with wooden case for outer packing
Delivery Time: 25 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 13,000 sets per quarter
Contact Now
Detailed Product Description
Function: Chill/Heat Indoor And Residential Hot Water EER: 3.30
COP: 4.90 Cooling Outlet: 8.20 To 14.8kw
Heating Outlet: 8.80 To 21.5kw Compressor: Mitsubishi Dual-rotary D/C Inverter
Refrigerant: R410A Cool Input: 2.50kw To 6.0kw
Heat Input: 2.2kw To 6.2kw Water Outlet: 07℃ To 60℃
Work Condtion: -20℃ To 45℃ Noise In 1M: Below 58 DB(A)

R410 Gas Japan Inverter Heat Pump Water Cooler and Heater Air Conditioning n Hot Water

 
R410 Gas Japan Inverter Heat Pump Water Cooler and Heater Air Conditioning n Hot Water Description:
 
1) Mitsubishi DC Inverter compressor with smart control system constructs outstanding COP even in cold region or country.
2) Most environment-friendly and high efficient regrigerant R410A.
3) Full consideration configurating and pipe construction for easy maintaining.
4) Low noise 6T inverter fan motor and ECO fan blade keep enough air energy to system in quiet enviroment.
5) Split type PCBs DC Inverter control system, high-efficiency heat radiator and boardband capacity to ensure system stability from burnt-out and achieving much as 30% energy saving.
 
R410 Gas Japan Inverter Heat Pump Water Cooler and Heater Air Conditioning n Hot Water Specification:

 

DC Inverter Heat Pump for cooling/heating & DHW
Item No. #PF050DC
Cooling Cooling Capacity(kw) 12.8
Capacity Range(kw) 8.2~14.8
Input Power(kw) 4.2
Input Power Range(kw) 2.5~6.0
Rated Current (A) 20.5
Current Range (A) 12.2~29.3
EER 3.05
EER Range 2.47~3.28
Heating Outlet(kw) 16.5
Outlet Range (kw) 10.7~21.5
Input Power (kw) 3.9
Input Power Range(kw) 2.2~5.9
Rated Current (A) 19
Current Range (A) 10.7~28.7
COP 4.23
COP Range 3.65~4.9
DHW Outlet(kW) 13.5
Outlet Range (kw) 8.8~17.6
Input Power(kw) 4.1
Input Power Range(kw) 2.3~6.2
Rated Current (A) 20
Current Range (A) 11.2~30.2
COP 3.29
COP Range 2.84~3.83
Compressor Mitsubishi Dual-rotary D/C Inverter Compressor
Refrigerant R410A
Power Supply 220V/50Hz
Working Area -20~43℃
Water Circulation(m³/h) 2.84
Water Pressure Drop(kPa) 30
IP Grade IPX4
Anti-electric shock Rate I
Noise in 1M dB(A) ≤58
N.W./G. W.(kg) 145/155
Pipe Size (mm) DN25
Unit Size(W*D*H) 1110*490*1260 mm
Packing Size(W*D*H) 1180*540*1390 mm
QTY (20'/40'/40'H) 18/42/42
Cooling work condition:Inlet water temp.12,outlet water temp.7,dry bulb temp.35,wet bulb temp.24.
Heating work condition:Inlet water temp.30,outlet water temp.35,dry bulb temp.7,wet bulb temp.6.
DHW work condition:Inlet water temp.15,outlet water temp.55,dry bulb temp.7,wet bulb temp.6.

3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511

R410 Gas Japan Inverter Heat Pump Water Cooler and Heater Air Conditioning n Hot Water Applications:

 

Business Organizations

supermarket, large-scale shopping malls, exclusive agency, chain shops, large-scale sales, star-rated hotels, restaurants, travel agencies, pharmacy.

Financial Organizations

Banks, negotiable securities, funds, insurance companies, pawnshops;
Non-profit Organizations: Telecommunications, post offices, hospital, schools;

Public Places

subway, airports, stations, gas stations, toll stations, bookstores, parks, exhibition halls, stadiums, museums, convention centers, ticket agencies, HR market, lottery centers; Real Estate Property: Apartments, villas, offices, commercial buildings, model rooms, property brokers;

Entertainments

Movie theaters, fitness halls, country clubs, clubs, massage rooms, bars, cafes, Internet bars, beauty shops, golf course

 
 
R410 Gas Japan Inverter Heat Pump Water Cooler and Heater Air Conditioning n Hot Water Advantages:
3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511
 
R410 Gas Japan Inverter Heat Pump Water Cooler and Heater Air Conditioning n Hot Water Installation Reference:
3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511


3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN145113.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511
 
R410 Gas Japan Inverter Heat Pump Water Cooler and Heater Air Conditioning n Hot Water in Production Line:
3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511
3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511
 
R410 Gas Japan Inverter Heat Pump Water Cooler and Heater Air Conditioning n Hot Water Shipping:
3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511

3.30 EER 4.90 High COP Heat Pump for 7℃ - 60℃ Water Outlet , CE ROHS EN14511
 
Save 30percent Energy Low Noise Inverter Heat Pump Chill Air Indoor Heating n Residential Hot Water welcome to visit Power World heat pump factory in Shenzhen and Dongguan! Please send me email: hp@heatpumpcn.com or WhatsApp/Mobile: +86-15099917097

Contact Details
Shenzhen Power World New Energy Technology Co., Ltd.

Contact Person: Ms. Ida Ray

Fax: 86-0755-33850799

Send your inquiry directly to us (0 / 3000)