Place of Origin: | China |
---|---|
Brand Name: | PowerWorld |
Certification: | CE,IEC,ISO |
Model Number: | PF030/050-DC |
Minimum Order Quantity: | 1unit |
Price: | 1000USD |
Packaging Details: | Plywood package . |
Delivery Time: | in 7 days for delivery . |
Payment Terms: | L/C, D/A, T/T, Western Union |
Supply Ability: | 100units / day |
Casing Color: | Anti-rusting Spray Coating | Package: | Plywood Package |
---|---|---|---|
Heating Capacity: | 9.5-17KW | COP: | Over 4.25 |
Compressor: | Dual-rotary D/C Inverter Compressor | Throttle Unit: | Thermal Expansion Valve |
Working Area: | -20~43℃ | Evaporator: | Blue Hydrophilic Fin And Copper Tube Heat Exchanger |
High Light: | coefficient of performance heat pump,air water heat pump |
10.2 & 16.5 Kw High Cop Heat Pump Heat Source Pump In Floor Heating Or Cooling
Fixed Speed System
Slowly gets to temperature as output rating is fixed. Then turns on and off to maintain room temperature.
Inverter System
Increased output to achieve set temperature faster. Then varies the output to maintain a constant room temperature.
A fixed speed system only has a single speed compressor motor that is either on or off. It works similar to a single speed fan heater running at its only speed that switches off when the desired temperature is reached and switches on again when the temperature drops to a set level. As there is only one speed that the fixed speed system can run at, it takes a lot longer to get to the desired temperature. As such this tends to lead to a lot more power usage in comparison to inverter driven systems.
Inverter technology uses a variable speed compressor motor similar to a car. It simply slows down and speeds up as needed to hold a selected comfort setting. This means the desired room temperature will be reached more quickly and maintained more efficiently.
Inverter technology provides a more precise room temperature without the fluctuations and power wastage of fixed speed systems. Inverter technology is significantly more energy efficient with energy savings of up to 30% over fixed speed systems.
The speed control of the outdoor unit also means quieter operation, this is important especially at night in residential areas.
Product model | PF030DC | PF050DC | |
Cooling | Cooling capacity(kW) | 7.7 | 12.8 |
Cooling capacity Min / Max(kW) | 4.9/8.9 | 8.2/14.8 | |
Cooling input power(kW) | 2.6 | 4.2 | |
Cooling input power Min / Max (kW) | 1.5/3.7 | 2.5/6.0 | |
Rated current (A) | 12.7 | 20.5 | |
Current Min / Max (A) | 7.3/18.1 | 12.2/29.3 | |
EER | 2.96 | 3.05 | |
EER Min / Max | 2.41/3.27 | 2.47/3.28 | |
Heating | Heating capacity(kW) | 10.2 | 16.5 |
Heating capacity Min / Max (kW) | 6.65/13.3 | 10.7/21.5 | |
Heating input power(kW) | 2.4 | 3.9 | |
Heating input power Min / Max (kW) | 1.4/3.6 | 2.2/5.9 | |
Rated current (A) | 11.7 | 19 | |
Current Min / Max (A) | 6.8/17.6 | 10.7/28.7 | |
COP | 4.25 | 4.23 | |
COP Min / Max | 3.69/4.75 | 3.65/4.9 | |
DHW | Heating capacity(kW) | 8.3 | 13.5 |
Heating capacity Min / Max (kW) | 5.4/10.8 | 8.8/17.6 | |
Heating input power(kW) | 2.5 | 4.1 | |
Heating input power Min / Max (kW) | 1.4/3.8 | 2.3/6.2 | |
Rated current (A) | 12 | 20 | |
Current Min / Max (A) | 6.8/18.5 | 11.2/30.2 | |
COP | 3.32 | 3.29 | |
COP Min / Max | 2.84/3.86 | 2.84/3.83 |
* Copeland Compressor :
Dual-rotary D/C Inverter Compressor .
* Fan:
Well selected axial T6 fan motor combined with large fan blade, which provide heavy air blow at low rotate speed, reducing vibration and noise.
*Danfoss Electric Expansion Valve:
Danfoss 500 steps Electronic Expansion valve, with more precise control of refrigerant flow system, which optimize heat pump working capacity and efficiency under different ambient conditions.
* High Efficient Tube in Shell Condenser (heat exchanger)
Optimize design of both inner and outer screwed tube, it helps to increase heating exchange efficiency, and provide better heating capacity. The special design of liquid refrigerant circulating tube on the bottom of condenser ensures the heat pump system run smoothly in severe working condition.
*Original DuPont Refrigerant
Original DuPont refrigerant, better efficient and ECO friendly, ensure heat pump run reliably and smoothly.
* Heat exchanger
Blue hydrophilic fin and copper tube heat exchanger.
*Outfitting both liquid-storage & gas-liquid separator
Our heat pump outfitting both liquid-storage and gas-liquid separator ensures units run smoothly in different kinds of extreme hostile environment.
*Eaton (USA) AC contactor & Thermal relay
High quality contactor and thermal relay can freely turn on/off more than 100,000 times.
* Humanized PCB Design
Military level PCB components, intelligent controlling program reinforced a reliable operation of the heat pump unit. Special colored wiring design on the PCB provides great convenience in installation and further maintenance.
*Wide Voltage Transformer
220V-240V or 380V-440V AC, 50/60Hz wide voltage transformer in case of voltage fluctuation, ensures unit work smoothly. Current transformer protecting over-current ensure unit working current more accurate.
*Aerial Noise Isolated Material
By using high quality aerial noise isolated material, noise and vibration is avoided perfectly.