Place of Origin: | China |
---|---|
Brand Name: | Powerworld |
Certification: | CE,ErP, RoHs |
Model Number: | PF030-DFXRS-S |
Minimum Order Quantity: | 1 |
Packaging Details: | Polywood packing |
Delivery Time: | 30 days against deposit |
Supply Ability: | 10000UNITS |
Material: | Galvanized Stainless Steel Powder Coated | Compressor: | Copeland/scroll |
---|---|---|---|
Expansion Valve: | Danfoss /Emerson | Refrigerant: | R407C |
Condensor: | Tube In Tube Heat Exchanger | Name: | Water/geothemal Heat Pump |
Residential Water / Ground Source Heat Pump Efficiency For Space Heating And Hot Water
There are four basic types of ground loop systems. Three of these -- horizontal, vertical, and
pond/lake -- are closed-loop systems. All of the approaches can be used for residential and commercial building applications.
Description:
1. High efficiency and energy saving
2. The high quality components,Using high efficient scroll compressor, plate heat exchanger, high efficient shell and tube heat exchanger, high efficient spiral casing heat exchanger, built-in WILO water pump (optional), good performance dot matrix controller.
3. The flexible installation , simple and easy
4. Integrated design, multiple protections. and reliable.
5. Integration design, system sealed welding completely,Multiple protections.such as water flow protection, compressor discharge temperature production, system refrigement high –low pressure protection , compressor overcurrent protection, power supply phase sequence protection,
6. Environmental Protection,Using R410 A refrigerants , CO2, zero emissions, no pollution, no waste gas, no waste discharge and green environmental protection
7. Simplicity of operator, Using a touch screen, dot matrix LCD display control, rolling language menu, easy to operate. Parametric design, display and monitor the unit operational status
8. The unit and the terminal equipment on-line control. The main machine automatically open when any terminal equipment is turned on; the main machine automatically shut down when all the terminal equipment is turned off.
9.Quiet running, Working environment meet the low temperature cold areas requestment, all-weather work reliable.
2. relative introduction
As with any heat pump, geothermal and water-source heat pumps are able to heat, cool, and, if so equipped, supply the house with hot water. Relative to air-source heat pumps, they are quieter, last longer, need little maintenance, and do not depend on the temperature of the outside air.
Even though the installation price of a geothermal system can be several times that of an air-source system of the same heating and cooling capacity, the additional costs are returned to you in energy savings in 5 to 10 years. System life is estimated at 25 years for the inside components and 50+ years for the ground loop. There are approximately 50,000 geothermal heat pumps installed in the United States each year. For more information, go to:
Specification
<Residential Water / ground source Heat Pump for space heating and hot water
Product model | PF030-DFXRS-S |
PF030- DFXRS |
PF050- DFXRS |
PF060- DFXRS |
PF100 -DFXRS |
PF120- DFXRS |
PF150- DFXRS |
PF200-DFXRS |
PF250- DFXRS |
PF300- DFXRS |
Heating capacity (kW) | 10.1 | 11.3 | 20.4 | 24.2 | 41.1 | 48.8 | 54.2 | 71.2 | 95 | 115 |
Input power (kW) | 2.08 | 2.33 | 4.22 | 5.02 | 8.48 | 10.1 | 11.2 | 14.8 | 19.8 | 23.9 |
Rated current (A) | 13 | 6 | 8.8 | 11.1 | 17.6 | 20.7 | 25.9 | 36.1 | 41.4 | 62 |
COP | 4.86 | 4.85 | 4.83 | 4.82 | 4.85 | 4.83 | 4.84 | 4.81 | 4.80 | 4.81 |
Rated outlet hot water temperature (℃) |
55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 |
Highest outlet hot water temperature(℃) |
60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 |
Production capacity (L/H) |
217 | 243 | 439 | 520 | 883 | 1049 | 1165 | 1530 | 2042 | 2472 |
Hot water Pipe size(mm) |
DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN50 | DN50 | DN65 | DN65 |
Heat sourc e inlet water temperature(℃) |
15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Heat source outlet water temperature(℃) |
10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Heat source circulation water capacity(L/H) |
3000 | 3400 | 5800 | 6700 | 11500 | 13500 | 15500 | 21200 | 27200 | 34500 |
Heat source pipe size(mm) |
DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN50 | DN50 | DN65 | DN65 |
IP Grade (Level of protection) |
IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 |
Anti-electric shock Rate | I | I | I | I | I | I | I | I | I | I |
Noise (dB(A)) | ≤55 | ≤55 | ≤58 | ≤58 | ≤62 | ≤62 | ≤66 | ≤66 | ≤70 | ≤70 |
Net weight(kg) | 90 | 90 | 125 | 135 | 280 | 300 | 372 | 482 | 582 | 650 |
Gross weight(kg) | 96 | 96 | 135 | 145 | 295 | 320 | 412 | 532 | 642 | 700 |
Metel plate |
Galvanized Spray/Gray |
|||||||||
Body size(W*D*H) |
710*520 *1000 |
710*520 *1000 |
710*520 *1000 |
710*520 *1000 |
1010*590 *1400 |
1010*590 *1400 |
1320*840 *1080 |
1750*1120 *900 |
1750*1120 *900 |
2000* 1120*900 |
Compressor | Copeland | |||||||||
Refrigerant | R407C | |||||||||
Power supply | 220V/50Hz | 380V/50Hz | 380V/50Hz | 380V/50Hz | 380V/50Hz | 380V/50Hz | 380V/50Hz | 380V/50Hz | 380V/50Hz | 380V/50Hz |
Condenser | Tube in tube heat exchanger | Tube in shell heat exchanger | ||||||||
Evaporator | Plate | Plate | Plate | Plate | Plate | Plate |
Shell and coiled |
|||
Expansion valve | Danfoss /Emerson |